2013-09-07 12:06:42 +02:00
|
|
|
|
|
|
|
--[[
|
2016-04-04 14:09:54 +02:00
|
|
|
|
2016-03-23 18:57:05 +01:00
|
|
|
Licensed under GNU General Public License v2
|
|
|
|
* (c) 2013, Luke Bonham
|
|
|
|
* (c) 2010-2012, Peter Hofmann
|
2016-04-04 14:09:54 +02:00
|
|
|
|
2013-09-07 12:06:42 +02:00
|
|
|
--]]
|
|
|
|
|
2013-09-10 23:02:11 +02:00
|
|
|
local newtimer = require("lain.helpers").newtimer
|
2013-09-07 12:06:42 +02:00
|
|
|
local first_line = require("lain.helpers").first_line
|
|
|
|
|
|
|
|
local naughty = require("naughty")
|
|
|
|
local wibox = require("wibox")
|
|
|
|
|
2016-06-25 17:51:21 +02:00
|
|
|
local math = { abs = math.abs,
|
|
|
|
floor = math.floor,
|
|
|
|
log10 = math.log10,
|
|
|
|
min = math.min }
|
2013-09-07 12:06:42 +02:00
|
|
|
local string = { format = string.format }
|
|
|
|
|
2016-07-06 10:33:23 +02:00
|
|
|
local type = type
|
2016-06-25 17:51:21 +02:00
|
|
|
local tonumber = tonumber
|
2013-09-07 12:06:42 +02:00
|
|
|
local setmetatable = setmetatable
|
|
|
|
|
|
|
|
-- Battery infos
|
|
|
|
-- lain.widgets.bat
|
|
|
|
|
2013-09-10 23:02:11 +02:00
|
|
|
local function worker(args)
|
2016-05-28 23:27:47 +02:00
|
|
|
local bat = {}
|
|
|
|
local args = args or {}
|
|
|
|
local timeout = args.timeout or 30
|
|
|
|
local batteries = args.batteries or (args.battery and {args.battery}) or {"BAT0"}
|
|
|
|
local ac = args.ac or "AC0"
|
2016-06-08 11:52:36 +02:00
|
|
|
local notify = args.notify or "on"
|
2016-05-31 10:44:51 +02:00
|
|
|
local settings = args.settings or function() end
|
2016-03-23 18:57:05 +01:00
|
|
|
|
2016-04-11 09:38:56 +02:00
|
|
|
bat.widget = wibox.widget.textbox('')
|
2016-03-23 18:57:05 +01:00
|
|
|
|
2016-04-11 09:38:56 +02:00
|
|
|
bat_notification_low_preset = {
|
2016-03-31 11:54:37 +02:00
|
|
|
title = "Battery low",
|
2016-04-11 09:38:56 +02:00
|
|
|
text = "Plug the cable!",
|
|
|
|
timeout = 15,
|
|
|
|
fg = "#202020",
|
|
|
|
bg = "#CDCDCD"
|
|
|
|
}
|
|
|
|
|
|
|
|
bat_notification_critical_preset = {
|
|
|
|
title = "Battery exhausted",
|
|
|
|
text = "Shutdown imminent",
|
|
|
|
timeout = 15,
|
|
|
|
fg = "#000000",
|
|
|
|
bg = "#FFFFFF"
|
|
|
|
}
|
|
|
|
|
2016-05-31 10:55:15 +02:00
|
|
|
bat_now = {
|
2016-06-13 09:08:05 +02:00
|
|
|
status = "N/A",
|
2016-05-31 10:55:15 +02:00
|
|
|
ac_status = "N/A",
|
|
|
|
perc = "N/A",
|
|
|
|
time = "N/A",
|
|
|
|
watt = "N/A"
|
|
|
|
}
|
2016-05-31 10:44:51 +02:00
|
|
|
|
2016-05-31 10:55:15 +02:00
|
|
|
bat_now.n_status = {}
|
|
|
|
for i = 1, #batteries do
|
2016-06-13 09:08:05 +02:00
|
|
|
bat_now.n_status[i] = "N/A"
|
2016-08-16 12:40:51 +02:00
|
|
|
bat_now.n_perc[i] = 0
|
2016-05-31 10:55:15 +02:00
|
|
|
end
|
|
|
|
|
|
|
|
function update()
|
2016-08-16 12:39:17 +02:00
|
|
|
local sum_rate_current = 0
|
|
|
|
local sum_rate_voltage = 0
|
|
|
|
local sum_rate_power = 0
|
|
|
|
local sum_rate_energy = 0
|
|
|
|
local sum_energy_now = 0
|
|
|
|
local sum_energy_full = 0
|
|
|
|
local pspath = "/sys/class/power_supply/"
|
2016-04-11 09:38:56 +02:00
|
|
|
|
2016-05-28 23:27:47 +02:00
|
|
|
for i, battery in ipairs(batteries) do
|
2016-06-23 10:14:10 +02:00
|
|
|
local bstr = pspath .. battery
|
2016-05-28 23:27:47 +02:00
|
|
|
local present = first_line(bstr .. "/present")
|
2016-04-11 09:38:56 +02:00
|
|
|
|
2016-06-23 10:14:10 +02:00
|
|
|
if tonumber(present) == 1 then
|
2016-05-28 23:27:47 +02:00
|
|
|
-- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
|
2016-08-16 12:39:17 +02:00
|
|
|
local rate_current = tonumber(first_line(bstr .. "/current_now"))
|
|
|
|
local rate_voltage = tonumber(first_line(bstr .. "/voltage_now"))
|
|
|
|
local rate_power = tonumber(first_line(bstr .. "/power_now"))
|
2016-04-11 09:38:56 +02:00
|
|
|
|
2016-05-28 23:27:47 +02:00
|
|
|
-- energy_now(P)[uWh], charge_now(I)[uAh]
|
|
|
|
local energy_now = tonumber(first_line(bstr .. "/energy_now") or
|
|
|
|
first_line(bstr .. "/charge_now"))
|
2016-04-11 09:38:56 +02:00
|
|
|
|
2016-05-28 23:27:47 +02:00
|
|
|
-- energy_full(P)[uWh], charge_full(I)[uAh]
|
|
|
|
local energy_full = tonumber(first_line(bstr .. "/energy_full") or
|
|
|
|
first_line(bstr .. "/charge_full"))
|
2016-04-11 09:38:56 +02:00
|
|
|
|
2016-05-28 23:27:47 +02:00
|
|
|
local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
|
|
|
|
math.floor((energy_now / energy_full) * 100)
|
2016-04-11 09:38:56 +02:00
|
|
|
|
2016-06-09 11:53:07 +02:00
|
|
|
bat_now.n_status[i] = first_line(bstr .. "/status") or "N/A"
|
2016-08-16 12:43:04 +02:00
|
|
|
bat_now.n_perc[i] = energy_percentage or bat_now.n_perc[i]
|
2016-08-16 12:39:17 +02:00
|
|
|
|
|
|
|
sum_rate_current = sum_rate_current + (rate_current or 0)
|
|
|
|
sum_rate_voltage = sum_rate_voltage + (rate_voltage or 0)
|
|
|
|
sum_rate_power = sum_rate_power + (rate_power or 0)
|
|
|
|
sum_rate_energy = sum_rate_energy + (rate_power or (((rate_voltage or 0) * (rate_current or 0)) / 1e6))
|
|
|
|
sum_energy_now = sum_energy_now + (energy_now or 0)
|
|
|
|
sum_energy_full = sum_energy_full + (energy_full or 0)
|
2016-05-28 23:27:47 +02:00
|
|
|
end
|
|
|
|
end
|
|
|
|
|
2016-05-31 10:44:51 +02:00
|
|
|
bat_now.status = bat_now.n_status[1]
|
2016-06-23 10:14:10 +02:00
|
|
|
bat_now.ac_status = tonumber(first_line(string.format("%s%s/online", pspath, ac))) or "N/A"
|
2016-06-13 09:08:05 +02:00
|
|
|
|
|
|
|
if bat_now.status ~= "N/A" then
|
|
|
|
-- update {perc,time,watt} iff battery not full and rate > 0
|
2016-06-26 13:43:20 +02:00
|
|
|
if bat_now.status ~= "Full" and (sum_rate_power > 0 or sum_rate_current > 0) then
|
2016-06-25 17:51:21 +02:00
|
|
|
local rate_time = 0
|
2016-06-26 13:43:20 +02:00
|
|
|
local div = (sum_rate_power > 0 and sum_rate_power) or sum_rate_current
|
2016-06-13 09:08:05 +02:00
|
|
|
|
|
|
|
if bat_now.status == "Charging" then
|
2016-06-26 13:43:20 +02:00
|
|
|
rate_time = (sum_energy_full - sum_energy_now) / div
|
2016-06-25 14:05:05 +02:00
|
|
|
else -- Discharging
|
2016-06-26 13:43:20 +02:00
|
|
|
rate_time = sum_energy_now / div
|
2016-06-13 09:08:05 +02:00
|
|
|
end
|
|
|
|
|
2016-06-26 13:43:20 +02:00
|
|
|
if rate_time < 0.01 then -- check for magnitude discrepancies (#199)
|
2016-06-25 17:51:21 +02:00
|
|
|
rate_time_magnitude = math.abs(math.floor(math.log10(rate_time)))
|
|
|
|
rate_time = rate_time * 10^(rate_time_magnitude - 2)
|
2016-06-25 14:05:05 +02:00
|
|
|
end
|
|
|
|
|
2016-08-16 12:39:17 +02:00
|
|
|
local hours = math.floor(rate_time)
|
|
|
|
local minutes = math.floor((rate_time - hours) * 60)
|
|
|
|
bat_now.perc = math.floor(math.min(100, (sum_energy_now / sum_energy_full) * 100))
|
|
|
|
bat_now.time = string.format("%02d:%02d", hours, minutes)
|
|
|
|
bat_now.watt = tonumber(string.format("%.2f", sum_rate_energy / 1e6))
|
2016-06-13 09:08:05 +02:00
|
|
|
elseif bat_now.status == "Full" then
|
2016-08-16 12:39:17 +02:00
|
|
|
bat_now.perc = 100
|
|
|
|
bat_now.time = "00:00"
|
|
|
|
bat_now.watt = 0
|
2016-04-11 09:38:56 +02:00
|
|
|
end
|
|
|
|
end
|
|
|
|
|
|
|
|
widget = bat.widget
|
|
|
|
settings()
|
|
|
|
|
|
|
|
-- notifications for low and critical states
|
2016-07-06 10:33:23 +02:00
|
|
|
if notify == "on" and type(bat_now.perc) == "number" and bat_now.status == "Discharging" then
|
2016-06-09 12:19:03 +02:00
|
|
|
if bat_now.perc <= 5 then
|
2016-04-11 09:38:56 +02:00
|
|
|
bat.id = naughty.notify({
|
|
|
|
preset = bat_notification_critical_preset,
|
2016-06-09 11:53:07 +02:00
|
|
|
replaces_id = bat.id
|
2016-04-11 09:38:56 +02:00
|
|
|
}).id
|
2016-06-09 12:19:03 +02:00
|
|
|
elseif bat_now.perc <= 15 then
|
2016-04-11 09:38:56 +02:00
|
|
|
bat.id = naughty.notify({
|
|
|
|
preset = bat_notification_low_preset,
|
2016-06-09 11:53:07 +02:00
|
|
|
replaces_id = bat.id
|
2016-04-11 09:38:56 +02:00
|
|
|
}).id
|
|
|
|
end
|
|
|
|
end
|
|
|
|
end
|
|
|
|
|
|
|
|
newtimer(battery, timeout, update)
|
|
|
|
|
|
|
|
return setmetatable(bat, { __index = bat.widget })
|
2013-09-07 12:06:42 +02:00
|
|
|
end
|
|
|
|
|
2015-09-19 10:44:38 +02:00
|
|
|
return setmetatable({}, { __call = function(_, ...) return worker(...) end })
|