mirror of https://github.com/lcpz/lain.git
Add possibility to give a list of batteries instead of only one.
This commit is contained in:
parent
6fd1eecd43
commit
5cdae1d0ba
|
@ -26,7 +26,7 @@ local function worker(args)
|
|||
local bat = {}
|
||||
local args = args or {}
|
||||
local timeout = args.timeout or 30
|
||||
local battery = args.battery or "BAT0"
|
||||
local batteries = args.batteries or (args.battery and {args.battery}) or {"BAT0"}
|
||||
local ac = args.ac or "AC0"
|
||||
local notify = args.notify or "on"
|
||||
local settings = args.settings or function() end
|
||||
|
@ -58,8 +58,15 @@ local function worker(args)
|
|||
watt = "N/A"
|
||||
}
|
||||
|
||||
local sum_rate_current = 0
|
||||
local sum_rate_voltage = 0
|
||||
local sum_rate_power = 0
|
||||
local sum_energy_now = 0
|
||||
local sum_energy_full = 0
|
||||
local sum_energy_percentage = 0
|
||||
|
||||
for i, battery in ipairs(batteries) do
|
||||
local bstr = "/sys/class/power_supply/" .. battery
|
||||
local astr = "/sys/class/power_supply/" .. ac
|
||||
local present = first_line(bstr .. "/present")
|
||||
|
||||
if present == "1"
|
||||
|
@ -80,29 +87,41 @@ local function worker(args)
|
|||
local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
|
||||
math.floor((energy_now / energy_full) * 100)
|
||||
|
||||
if bat_now.status ~= "Charging" and bat_now.status ~= "Discharging"
|
||||
then
|
||||
bat_now.status = first_line(bstr .. "/status") or "N/A"
|
||||
end
|
||||
|
||||
sum_rate_current = sum_rate_current + (rate_current or 0)
|
||||
sum_rate_voltage = sum_rate_voltage + rate_voltage
|
||||
sum_rate_power = sum_rate_power + (rate_power or ((rate_voltage * rate_current) / 1e6))
|
||||
sum_energy_now = sum_energy_now + energy_now
|
||||
sum_energy_full = sum_energy_full + energy_full
|
||||
sum_energy_percentage = sum_energy_percentage + energy_percentage
|
||||
end
|
||||
end
|
||||
|
||||
local astr = "/sys/class/power_supply/" .. ac
|
||||
bat_now.ac_status = first_line(astr .. "/online") or "N/A"
|
||||
|
||||
-- update {perc,time,watt} iff rate > 0 and battery not full
|
||||
if ((rate_current and rate_current > 0) or (rate_power and rate_power > 0))
|
||||
if ((sum_rate_current > 0) or (sum_rate_power > 0))
|
||||
and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
|
||||
then
|
||||
local rate_time = 0
|
||||
if bat_now.status == "Charging" then
|
||||
rate_time = (energy_full - energy_now) / (rate_power or rate_current)
|
||||
rate_time = (sum_energy_full - sum_energy_now) / (sum_rate_power or sum_rate_current)
|
||||
elseif bat_now.status == "Discharging" then
|
||||
rate_time = energy_now / (rate_power or rate_current)
|
||||
rate_time = sum_energy_now / (sum_rate_power or sum_rate_current)
|
||||
end
|
||||
|
||||
local hours = math.floor(rate_time)
|
||||
local minutes = math.floor((rate_time - hours) * 60)
|
||||
local watt = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
|
||||
|
||||
bat_now.perc = string.format("%d", math.min(100, energy_percentage))
|
||||
local watt = sum_rate_power / 1e6
|
||||
bat_now.perc = string.format("%d", math.min(100, sum_energy_percentage / table.getn(batteries)))
|
||||
bat_now.time = string.format("%02d:%02d", hours, minutes)
|
||||
bat_now.watt = string.format("%.2fW", watt)
|
||||
end
|
||||
end
|
||||
|
||||
widget = bat.widget
|
||||
settings()
|
||||
|
|
Loading…
Reference in New Issue