lain/widgets/bat.lua

159 lines
5.8 KiB
Lua

--[[
Licensed under GNU General Public License v2
* (c) 2013, Luke Bonham
* (c) 2010-2012, Peter Hofmann
--]]
local newtimer = require("lain.helpers").newtimer
local first_line = require("lain.helpers").first_line
local naughty = require("naughty")
local wibox = require("wibox")
local math = { floor = math.floor, min = math.min }
local string = { format = string.format }
local tonumber = tonumber
local setmetatable = setmetatable
-- Battery infos
-- lain.widgets.bat
local function worker(args)
local bat = {}
local args = args or {}
local timeout = args.timeout or 30
local batteries = args.batteries or (args.battery and {args.battery}) or {"BAT0"}
local ac = args.ac or "AC0"
local notify = args.notify or "on"
local settings = args.settings or function() end
bat.widget = wibox.widget.textbox('')
bat_notification_low_preset = {
title = "Battery low",
text = "Plug the cable!",
timeout = 15,
fg = "#202020",
bg = "#CDCDCD"
}
bat_notification_critical_preset = {
title = "Battery exhausted",
text = "Shutdown imminent",
timeout = 15,
fg = "#000000",
bg = "#FFFFFF"
}
bat_now = {
status = "N/A",
ac_status = "N/A",
perc = "N/A",
time = "N/A",
watt = "N/A"
}
bat_now.n_status = {}
for i = 1, #batteries do
bat_now.n_status[i] = "N/A"
end
function update()
local sum_rate_current = 0
local sum_rate_voltage = 0
local sum_rate_power = 0
local sum_energy_now = 0
local sum_energy_full = 0
local sum_energy_percentage = 0
local pspath = "/sys/class/power_supply/"
for i, battery in ipairs(batteries) do
local bstr = pspath .. battery
local present = first_line(bstr .. "/present")
if tonumber(present) == 1 then
-- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
local rate_current = tonumber(first_line(bstr .. "/current_now"))
local rate_voltage = tonumber(first_line(bstr .. "/voltage_now"))
local rate_power = tonumber(first_line(bstr .. "/power_now"))
-- energy_now(P)[uWh], charge_now(I)[uAh]
local energy_now = tonumber(first_line(bstr .. "/energy_now") or
first_line(bstr .. "/charge_now"))
-- energy_full(P)[uWh], charge_full(I)[uAh]
local energy_full = tonumber(first_line(bstr .. "/energy_full") or
first_line(bstr .. "/charge_full"))
local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
math.floor((energy_now / energy_full) * 100)
bat_now.n_status[i] = first_line(bstr .. "/status") or "N/A"
sum_rate_current = sum_rate_current + (rate_current or 0)
sum_rate_voltage = sum_rate_voltage + rate_voltage
sum_rate_power = sum_rate_power + (rate_power or ((rate_voltage * rate_current) / 1e6))
sum_energy_now = sum_energy_now + (energy_now or 0)
sum_energy_full = sum_energy_full + energy_full
sum_energy_percentage = sum_energy_percentage + energy_percentage
end
end
bat_now.status = bat_now.n_status[1]
bat_now.ac_status = tonumber(first_line(string.format("%s%s/online", pspath, ac))) or "N/A"
if bat_now.status ~= "N/A" then
-- update {perc,time,watt} iff battery not full and rate > 0
if bat_now.status ~= "Full" and (sum_rate_current > 0 or sum_rate_power > 0) then
local rate_time = 0
local sum_rpc = sum_rate_power or sum_rate_current
if sum_rpc >= 1e8 then sum_rpc = sum_rpc / 10 end
if bat_now.status == "Charging" then
rate_time = (sum_energy_full - sum_energy_now) / sum_rpc
elseif bat_now.status == "Discharging" then
rate_time = sum_energy_now / sum_rpc
end
local hours = math.floor(rate_time)
local minutes = math.floor((rate_time - hours) * 60)
bat_now.perc = tonumber(string.format("%d", math.min(100, sum_energy_percentage / #batteries)))
bat_now.time = string.format("%02d:%02d", hours, minutes)
bat_now.watt = tonumber(string.format("%.2f", sum_rate_power / 1e6))
elseif bat_now.status == "Full" then
bat_now.perc = 100
bat_now.time = "00:00"
bat_now.watt = 0
end
end
widget = bat.widget
settings()
-- notifications for low and critical states
if notify == "on" and bat_now.perc and bat_now.status == "Discharging" then
if bat_now.perc <= 5 then
bat.id = naughty.notify({
preset = bat_notification_critical_preset,
replaces_id = bat.id
}).id
elseif bat_now.perc <= 15 then
bat.id = naughty.notify({
preset = bat_notification_low_preset,
replaces_id = bat.id
}).id
end
end
end
newtimer(battery, timeout, update)
return setmetatable(bat, { __index = bat.widget })
end
return setmetatable({}, { __call = function(_, ...) return worker(...) end })